Reduced Voltage Starters -
Primary Resistor Type
- Class 8547, 8549
The Class 8547 (reversing) and 8549 (non-reversing)
primary resistor starters are used when squirrel cage motors need
starting with low current to avoid power line disturbances, or low
torque to prevent equipment damage.
|
Maximum Horsepower |
Volts |
NEMA Size |
Thermal units Required |
NEMA Type 1 |
NEMA Type 12 |
|
2 Pole Single Phase |
2 |
115-230 |
1 |
1 |
SCG-1 |
SCA-1 |
|
3 |
115
230 |
1P
1 |
1
1 |
SCG-2
SCG-1 |
SCA-2
SCA-1 |
|
5 |
230 |
1P |
1 |
SCG-2 |
SCA-2 |
|
7 1/2 |
230 |
2 |
1 |
SDG-1 |
SDA-1 |
|
10 |
230 |
3 |
1 |
SEG-1 |
SEA-1 |
|
15 |
230 |
3 |
1 |
SEG-1 |
SEA-1 |
|
3 Pole
Three Phase |
5 |
200-230
380-575 |
1 |
3 |
SCG-3 |
SCA-3 |
SCG-1 |
|
7 1/2 |
200-230
380-575 |
1 |
3 |
SCG-3 |
SCA-3 |
SCG1 |
|
10 |
200-230
380-575 |
2
1 |
3 |
SDG-2
SCG-3 |
SDA-2
SCA-3 |
SDG-1
SCG-1 |
|
15 |
200
230
380-575 |
3
2
2 |
3 |
SEG-2
SDG-2
SDG-2 |
SEA-2
SDA-2
SDA-2 |
SEG-1
SDG-1
SDG-1 |
|
20 |
200-230
380-575 |
3
2 |
3 |
SEG-2
SDG-2 |
SEA-2
SDA-2 |
SEG-1
SDG-1 |
|
25 |
200-230
380-575 |
3
2 |
3 |
SEG-2
SDG-2 |
SEA-2
SDA-2 |
SEG-1
SDG-1 |
|
30 |
200
230
380-575 |
4
3
3 |
3 |
SFG-1
SEG-2
SEG-2 |
SFA-1
SEA-2
SEA-2 |
SFG-1
SEG-1
SEG-1 |
|
40 |
200-230
380-575 |
4
3 |
3 |
SFG-1
SEG-2 |
SFA-1
SEA-2 |
SFG-1
SEG-1 |
|
50 |
200
230
380-575 |
5
4
3 |
3 |
SGG-1
SFG-1
SEG-2 |
SGA-1
SFA-1
SEA-2 |
SGG-1
SFG-1
SEG-1 |
|
75 |
200-230
380-575 |
5
4 |
3 |
SGG-1
SFG-1 |
SGA-1
SFA-1 |
SGG-1
SFG-1 |
|
100 |
200
230
380
460-575 |
6
5
5
4 |
3 |
SHG-1
SGG-1
SGG-1
SFG-1 |
SHA-1
SGA-1
SGA-1
SFA-1 |
.....
SGG-1
SGG-1
SFG-1 |
|
125 |
200-230
380-575 |
6
5 |
3 |
SHG-1
SGG-1 |
SHA-1
SGA-1 |
.....
SGG-1 |
|
150 |
200-230
380-575 |
6
5 |
3 |
SHG-1
SGG-1 |
SHA-1
SGA-1 |
.....
SGG-1 |
|
200 |
230
380
460-575 |
6
6
5 |
3 |
SHG-1
SHG-1
SGG-1 |
SHA-1
SHA-1
SGA-1 |
.....
.....
SGG-1 |
|
250 |
230
380-575 |
7
6 |
3 |
SJG-1
SHG-1 |
SJA-1
SHG-1 |
|
|
300 |
230
380-575 |
7
6 |
3 |
KG-1
SHG-1 |
KA-1
SHA-1 |
|
|
400 |
230
460-575 |
8
6 |
3 |
KG-1
SHG-1 |
KA-1
SHA-1 |
|
|
450 |
230
460-575 |
8
7 |
3 |
KG-1
SJG-1 |
KA-1
SJA-1 |
|
|
500 |
460-575 |
7 |
3 |
SJG-1 |
SJA-1 |
|
|
600 |
460-575 |
7 |
3 |
SJG-1 |
SJA-1 |
|
|
700 |
460-575 |
8 |
3 |
KG-1 |
KA-1 |
|
|
800 |
460-575 |
8 |
3 |
KG-1 |
KA-1 |
|
|
900 |
460-575 |
8 |
3 |
KG-1 |
KA-1 |
|
[Back to Top]
Reduced Voltage Starters -
Multi-Point
Primary Resistor Type - Class 8547
Multi-Point starters are used when power companies
specify a maximum value of current that can be drawn from the power line
when starting a motor. The Square D Class 8547 Multi-Point Primary
Resistor starters provide equal current increments.
50-60 Hertz |
3 Pole
200-275 Volts |
Max. Horsepower |
Volts |
Final Contactor NEMA Size |
2 Point Acceleration |
3 Point Acceleration |
4 Point Acceleration |
5 Point Acceleration |
6 Point Acceleration |
10 |
200-230
380-575 |
2
1 |
SCG-5
SCG-7 |
SDG-8
SDG-8 |
|
|
|
15 |
200
230
380-575 |
3
2
2 |
SEG-8
SDG-5
SDG-5 |
SEG-9
SDG-6
SDG-6 |
|
|
|
20 |
200-230
380-575 |
3
2 |
SEG-8
SDG-5 |
SEG-9
SDG-6 |
SEG-10
..... |
|
|
25 |
200-230
380-575 |
3
2 |
SEG-8
SDG-5 |
SEG-9
SDG-6 |
SEG-10
..... |
|
|
30 |
200
230
380-575 |
4
3
3 |
SFG-3
SEG-8
SEG-8 |
SEG-9
SDG-6 |
SEG-5
SEG-10
SEG-10 |
SFG-6
.....
..... |
|
40 |
200-230
380-575 |
4
3 |
SFG-3
SEG-8 |
SFG-4
SEG-9 |
SFG-5
SEG-10 |
SFG-6
SFG-6 |
|
50 |
200
230
380-575 |
5
4
3 |
SGG-4
SFG-3
SEG-8 |
SGG-5
SFG-4
SEG-9 |
SGG-7
SFG-5
SEG-10 |
SGG-9
SFG-6
..... |
SGG-11
.....
..... |
60 |
200-230
380-575 |
5
4 |
SGG-4
SFG-3 |
SGG-5
SFG-4 |
SGG-7
SFG-5 |
SGG-9
SFG-6 |
SGG-11
SGG-6 |
75 |
200-230
380-575 |
5
4 |
SGG-4
SFG-3 |
SGG-6
SGG-6
SFG-4 |
SGG-7
SFG-5 |
SGG-9
SFG-6 |
SGG-12
..... |
100 |
230
380
460-575 |
5
5
4 |
SGG-4
SGG-4
SFG-3 |
SGG-5 |
SGG-8
SGG-8
SFG-5 |
SGG-10
SGG-10
SFG-6 |
SGG-13
SGG-13
..... |
125 |
380-575 |
5 |
SGG-4 |
SGG-5 |
SGG-7 |
SGG-9 |
SGG-11 |
150 |
380-575 |
5 |
SGG-4 |
SGG-5 |
SGG-7 |
SGG-9 |
SGG-12 |
200 |
460-575 |
5 |
SGG-4 |
SGG-6 |
SGG-8 |
SGG-10 |
SGG-13 |
[Back to Top]
Reduced Voltage Starters -
Vari-Torq
Adjustable Reactor Type - Class 8604
Square D Class 8604 reactor type starters are similar to
the Class 8547 primary resistor starters, except for adjustable reactors
replace the resistors. Please call for part numbers and applications.
Reduced Voltage Starters -
Autotransformer Type - Class
8606
Starters are provided with taps to select 50%, 65%, or
80% voltage to the motor while starting. The taps permit adjustment to
select the proper voltage for the right amount of torque.
50-60Hz |
Three Melting Allow Thermal
Relays
600 Volts Max. |
Max HP Ratings |
Volts |
NEMA Size |
NEMA Type 1 |
NEMA Type 4 |
NEMA Type 9 |
NEMA Type 12 |
Open Type |
10 |
200-230
380-575 |
2 |
SDG-1 |
SDW-1 |
SDE-1 |
SDA-1 |
SDO-1 |
15 |
200
230
380-575 |
3
2
2 |
SEG-1
SDG-1
SDG-1 |
SEW-1
SDW-1
SDW-1 |
SEE-1
SDE-1
SDE-1 |
SEA-1
SDA-1
SDA-1 |
SE0-1
SD0-1
SD0-1 |
25 |
200-230
380-575 |
3
2 |
SEG-1
SDG-1 |
SEW-1
SDW-1 |
SEE-1
SDE-1 |
SEA-1
SDA-1 |
SEO-1
SDO-1 |
30 |
200
230
380-575 |
4
3
3 |
SFG-1
SEG-1
SEG-1 |
SFW-1
SEW-1
SEW-1 |
SEE-1
SEE-1
SEE-1 |
SFA-1
SEA-1
SEA-1 |
SFO-1
SEO-1
SEO-1 |
40 |
200-230
380-575 |
4
3 |
SFG-1
SEG-1 |
SFW-1
SEW-1 |
SFE-1
SEE-1 |
SFA-1
SEA-1 |
SFO-1
SEO-1 |
50 |
200
230
380-575 |
5
4
3 |
SGG-1
SFG-1
SEG-1 |
SGW-1
SFW-1
SEW-1 |
.....
SFE-1
SEE-1 |
SGA-1
SFA-1
SEA-1 |
SGO-1
SFO-1
SEO-1 |
75 |
200-230
380-575 |
5
4 |
SGG-1
SFG-1 |
SGW-1
SFW-1 |
.....
SFE-1 |
SGA-1
SFA-1 |
SGO-1
SFO-1 |
100 |
200
230
380
460-575 |
6
5
5
4 |
SHG-1
SGG-1
SGG-1
SFG-1 |
SHW-1
SGW-1
SGW-1
SFW-1 |
.....
.....
.....
SFE-1 |
SHA-1
SGA-1
SGA-1
SFA-1 |
SHO-1
SGO-1
SGO-1
SFO-1 |
125 |
200
230
380-575 |
6
6
5 |
SHG-1
SHG-1
SGG-1 |
SHW-1
SHW-1
SGW-1 |
|
SHA-1
SHA-1
SGA-1 |
SHO-1
SHO-1
SGO-1 |
150 |
200
230
380-575 |
6
6
5 |
SHG-1
SHG-1
SGG-1 |
SHW-1
SHW-1
SGW-1 |
|
SHA-1
SHA-1
SGA-1 |
SHO-1
SHO-1
SGO-1 |
200 |
230
380
460-575 |
6
6
5 |
SHG-1
SHG-1
SGG-1 |
SHW-1
SHW-1
SGW-1 |
|
SHA-1
SHA-1
SGA-1 |
SHO-1
SHO-1
SGO-1 |
250 |
203
380-575 |
7
6 |
SJG-1
SHG-1 |
SJG-1
SHG-1 |
|
SJA-1
SHA-1 |
.....
SHO-1 |
300 |
230
380-575 |
7
6 |
SJG-1
SHG-1 |
SJW-1
SHW-1 |
|
SJA-1
SHA-1 |
.....
SHO-1 |
400 |
230
460-575 |
8
6 |
KG-1
SHG-1 |
KW-1
SHW-1 |
|
KA-1
SHW-1 |
.....
SHO-1 |
450 |
230
460-575 |
8
7 |
KG-1
SHG-1 |
KW-1
SHW-1 |
|
KA-1
SHA-1 |
|
500 |
460-575 |
7 |
SJG-1 |
SJW-1 |
|
SJA-1 |
|
600 |
460-575 |
7 |
SJG-1 |
SJW-1 |
|
SJA-1 |
|
700 |
460-575 |
8 |
KG-1 |
KW-1 |
|
KA-1 |
|
800 |
460-575 |
8 |
KG-1 |
KW-1 |
|
KA-1 |
|
900 |
460-575 |
8 |
KG-1 |
KW-1 |
|
KA1 |
|
[Back to Top]
Reduced Voltage Starters -
Wye Delta Type - Class 8630
The Square D Class 8630 Wye-Delta starters may only be
used with 6 lead (Wye Delta) motors. The starters connect to the motor
windings in Wye for starting, then in delta for running. The Class 8360
starter utilizes three melting allow overload relays.
600 Volts Max Three Melting Alloy Overload Relays 50-60 Hertz |
|
Open Transition Starting |
Closed Transition Starting |
Max
HP |
Voltage |
NEMA Size |
NEMA Type 1 |
NEMA Type 4 |
NEMA Type 12 |
Open Type |
NEMA Type 1 |
NEMA Type 4 |
NEMA Type 12 |
Open Type |
10 |
200-230
380-575 |
1YD
1YD |
SCG-1
SCG-1 |
SCW-11
SCW-11 |
SCA-1
SCA-1 |
SCO-1
SCO-1 |
SCG-2
SCG-2 |
SCW-12
SCW-12 |
SCA-2
SCA-2 |
SCO-2
SCO-2 |
15 |
200-230
380-575 |
2YD
1YD |
SDG-1
SCG-1 |
SDW-11
SCW-11 |
SDA-1
SCA-1 |
SDO-1
SCO-1 |
SDG-2
SCG-2 |
SDW-12
SCW-12 |
SDA-2
SCA-2 |
SDO-2
SCO-2 |
20 |
200-230
380-575 |
2YD
2YD |
SDG-1
SDG-1 |
SDW-11
SDW-11 |
SDA-1
SDA-1 |
SDO-1
SDO-1 |
SDG-2
SDG-2 |
SDW-12
SDW-12 |
SDA-2
SDA-2 |
SDO-2
SDO-2 |
25 |
200
230
380-575 |
3YD
2YD
2YD |
SEG-1
SDG-1
SDG-1 |
SEW-11
SDW-11
SDW-11 |
SEA-1
SDA-1
SDA-1 |
SEO-1
SDO-1
SDO-1 |
SEG-2
SDG-2
SDG-2 |
SEW-12
SDW-12
SDW-12 |
SEA-2
SDA-2
SDA-2 |
SEO-2
SDO-2
SDO-2 |
30 |
200-230
380-575 |
3YD
2YD |
SEG-1
SDG-1 |
SEW-11
SDW-11 |
SEA-1
SDA-1 |
SEO-1
SDO-1 |
SEG-2
SDG-2 |
SEW-12
SDW-12 |
SEA-2
SDA-2 |
SEO-2
SDO-2 |
40 |
200-230
380-575 |
3YD
2YD |
SEG-1
SDG-1 |
SEW-11
SDW-11 |
SEA-1
SDA-1 |
SEO-1
SDO-1 |
SEG-2
SDG-2 |
SEW-12
SDW-12 |
SEA-2
SDA-2 |
SEO-2
SDO-2 |
50 |
200
230
380-575 |
4YD
3YD
3YD |
SFG-1
SEG-1
SEG-1 |
SFW-11
SEW-11
SEW-11 |
SFA-1
SEA-1
SEA-1 |
SFO-1
SEO-1
SEO-1 |
SFG-2
SEG-2
SEG-2 |
SFW-12
SEW-12
SEW-12 |
SFA-2
SEA-2
SEA-2 |
SFO-2
SEO-2
SEO-2 |
60 |
200-230
380-575 |
4YD
3YD |
SFG-1
SEG-1 |
SFW-11
SEW-11 |
SFA-1
SEW-1 |
SFO-1
SEO-1 |
SFG-2
SEG-2 |
SFW-12
SFW-12 |
SFA-2
SFA-2 |
SFO-2
SFO-2 |
75 |
200
230
380-575 |
5YD
4YD
3YD |
SGG-1
SFG-1
SEG-1 |
SGW-1
SFW-11
SEW-11 |
SGA-1
SFA-1
SEA-1 |
SGO-1
SFO-1
SEO-1 |
SGG-2
SFG-2
SEG-2 |
SGW-2
SFW-12
SEW-12 |
SGA-2
SFA-2
SEA-2 |
SGO-2
SFO-2
SEO-2 |
100 |
200-230
380-575 |
5YD
4YD |
SGG-1
SFG-1 |
SGW-1
SFW-11 |
SGA-1
SFA-1 |
SGO-1
SFO-1 |
SGG-2
SFG-2 |
SGW-2
SFW-12 |
SGA-2
SFA-2 |
SGO-2
SFO-2 |
150 |
200-230
380-575 |
5YD
4YD |
SGG-1
SFG-1 |
SGW-1
SFW-11 |
SGA-1
SFA-1 |
SGO-1
SFO-1 |
SGG-2
SFG-2 |
SGW-2
SFW-12 |
SGA-2
SFA-2 |
SGO-2
SFO-2 |
250 |
200-230
380-575 |
6YD
5YD |
SHG-1
SGG-1 |
SHW-1
SGW-1 |
SHA-1
SGA-1 |
SHO-1
SGO-1 |
SHG-2
SGG-2 |
SHW-2
SGW-2 |
SHA-2
SGA-2 |
SHO-2
SGO-2 |
300 |
200-230
380
460-575 |
6YD
6YD
5YD |
SHG-1
SHG-1
SGG-1 |
SHW-1
SHW-1
SGG-1 |
SHA-1
SHA-1
SGA-1 |
SHO-1
SHO-1
SGO-1 |
SHG-2
SHG-2
SGG-2 |
SHW-2
SHW-2
SGW-2 |
SHA-2
SHA-2
SGA-2 |
SHO-2
SHO-2
SGO-2 |
350 |
200
380
380-575 |
7YD
6YD
6YD |
SJG-1
SHG-1
SHG-1 |
SJW-1
SHW-1
SHW-1 |
SJA-1
SHA-1
SHA-1 |
SJO-1
SHO-1
SHO-1 |
SJG-2
SHG-2
SHG-2 |
SJW-2
SHW-2
SHW-2 |
SJA-2
SHA-2
SHA-2 |
SJO-2
SHO-2
SHO-2 |
500 |
200-230
380-575 |
7YD
6YD |
SJG-1
SHG-1 |
SJW-1
SHW11 |
SJA-1
SHA-1 |
SJO-1
SHO-1 |
SJG-2
SHG-2 |
SJW-2
SHW-2 |
SJA-2
SHA-2 |
SJO-2
SHO-2 |
600 |
200-230
380
460-575 |
8YD
7YD
6YD |
KG-1
SJG-1
SHG-1 |
KW-1
SJW-1
SHW-1 |
KA-1
SJA-1
SHA-1 |
KO-1
SJO-1
SHO-1 |
KG-3
SJG-2
SHG-2 |
KW-2
SJW-2
SHW-2 |
KA-2
SJA-2
SHA-2 |
KO-2
SJO-2
SHO-2 |
700 |
200-230
380
460-575 |
8YD
7YD
6YD |
KG-1
SJG-1
SHG-1 |
KW-1
SJW-1
SHW-1 |
KA-1
SJA-1
SHA-1 |
KO-1
SJO-1
SHO-1 |
KG-2
SJG-2
SHG-2 |
KW-2
SJW-2
SHW-2 |
KA-2
SJA-2
SHA-2 |
KO-2
SJO-2
SHO-2 |
750 |
200-230
380-575 |
8YD
7YD |
KG-1
SJG-1 |
KW-1
SJW-1 |
KA-1
SJA-1 |
KO-1
SJO-1 |
KG-2
SJG-2 |
KW-2
SJW-2 |
KA-2
SJA-2 |
KO-2
SJO-2 |
800 |
230
380-575 |
8YD
7YD |
KG-1
SJG-1 |
KW-1
SJW-1 |
KA-1
SJA-1 |
KO-1
SJO-1 |
KG-2
SJG-2 |
KW-2
SJW-2 |
KA-2
SJA-2 |
KO-2
SJO-2 |
1000 |
380
460-575 |
8YD
7YD |
KG-1
SHG-1 |
KW-1
SHW-1 |
KA-1
SHA-1 |
KO-1
SHO-1 |
KG-2
SHG-2 |
KW-2
SHW-2 |
KA-2
SHA-2 |
KO-2
SHO-2 |
1500 |
460-575 |
8YD |
KG-1 |
KW-1 |
KA-1 |
KO-1 |
KG-2 |
SW-2 |
KA-2 |
KO-2 |
[Back to Top]
Reduced Voltage Starters -
Part Winding Class 8640
The Square D Part winding starters are used to start
motors with two sets of windings and can be started with only one. After
starting the second winding is connected. There are hand reset melting
thermal units for each winding.
Six Melting Alloy Overload Relays
600V Max |
Motor Voltage |
Max HP Poly Phase |
NEMA Size |
NEMA Type 1 |
NEMA Type 4 |
NEMA Type 9 |
NEMA Type 12 |
Open Type |
200 |
10
20
40
75
150 |
1PW
2PW
3PW
4PW
5PW |
SCG-1
SDG-1
SEG-1
SFG-1
SGG-1 |
SCW-11
SDW-11
SEW-11
SFW-11
SGW-11 |
SCE-1
SDE-1
SEE-1
SFE-1
..... |
SCA-1
SDA-1
SEA-1
SFA-1
SGA-1 |
SCO-1
SDO-1
SEO-1
SFO-1
SGO-1 |
230 |
10
25
50
75
150
300
450 |
1PW
2PW
3PW
4PW
5PW
6PW
7PW |
SCG-1
SDG-1
SEG-1
SFG-1
SGG-1
SGH-1
SJG-1 |
SCW-11
SDW-11
SEW-11
SFW-11
SGW-11
SHW-11
SJW-11 |
SCE-1
SDE-1
SEE-1
SFE-1
.....
..... |
SCA-1
SDA-1
SEA-1
SFA-1
SGA-1
SHA-1
SJA-1 |
SCO-1
SDO-1
SEO-1
SFO-1
SGO-1
SHO-1
SJO-1 |
460-575 |
15
40
75
750
350
600
900 |
1PW
2PW
3PW
4PW
5PW
6PW
7PW |
SCG-1
SDG-1
SEG-1
SFG-1
SGG-1
SHG-1
SJG-1 |
SCW-11
SDW-11
SEW-11
SFW-11
SGW-11
SHW-11
SJW-11 |
SCE-1
SDE-1
SEE-1
SFE-1
.....
.....
..... |
SCA-1
SDA-1
SEA-1
SFA-1
SGA-1
SHA-1
SJA-1 |
SCO-1
SDO-1
SEO-1
SFO-1
SGO-1
SHO-1
SJO-1 |
[Back to Top]
Reduced Voltage Starters -
Wound Rotor
Type - Class 8650, 8651
Wound rotor or slip ring motors can be started with the
Square D Class 8560 and 8651 non-reversing, and reversing starters.
Starters have three hand reset melting overload relays.
HP Rating |
NEMA Size of Primary Contactor |
Volts |
Acceleration Points |
NEMA Type 1 |
NEMA Type 12 |
3 |
1 |
200-230
380-575 |
2 |
SCG-1 |
SCA-1 |
5 |
1 |
200-230
380-575 |
2 |
SCG-1 |
SCA-1 |
7 1/2 |
1 |
200-230
380-575 |
2 |
SCG-1 |
SCA-1 |
10 |
2
1 |
200-230
380-575 |
2 |
SDG-1
SCG-1 |
SDA-1
SCA-1 |
15 |
3
2
2 |
200
230
380-575 |
2 |
SEG-2
SDG-1
SDG-1 |
SEA-2
SDA-2
SDA-2 |
20 |
3
2 |
200-230
380-575 |
3 |
SEG-1
SDG-2 |
SEA-1
SDA-2 |
25 |
3
2 |
200-230
380-575 |
3 |
SEG-1
SDG-1 |
SEA-1
SDA-1 |
30 |
4
3
3 |
200
230
380-575 |
3 |
SFG-1
SEG-1
SEG-1 |
SFA-1
SEA-1
SEA-1 |
40 |
4
3 |
200-230
380-575 |
3 |
SFG-1
SEG-1 |
SFA-1
SEA-1 |
50 |
5
4
3 |
200
230
380-575 |
3 |
SGG-1
SFG-1
SEG-1 |
SGA-1
SFA-1
SEA-1 |
60 |
5
4 |
200-230
380-575 |
3 |
SGG-1
SFG-1 |
SGA-1
SFA-1 |
75 |
5
4 |
200-230
380-575 |
3 |
SGG-1
SFG-1 |
SGA-1
SFA-1 |
100 |
6
5
5
4 |
200
230
380
460-575 |
4 |
SHG-1
SGG-2
SGG-2
SFG-2 |
SHA-1
SGA-1
SGA-1
SFA-2 |
125 |
6
5 |
200-230
380-575 |
4 |
SHG-1
SGG-2 |
SHA-1
SGA-2 |
150 |
6
5 |
200-230
380-575 |
4 |
SHG-1
SGG-2 |
SHA-1
SGA-2 |
200 |
6
6
5 |
230
380
460-575 |
5 |
SHG-2
SHG-2
SGG-3 |
SHA-2
SHA-2
SGA-2 |
250 |
7
6 |
230
380-575 |
5 |
SJG-1
SHG-2 |
SJA-1
SHA-2 |
300 |
7
6 |
230
380-575 |
5 |
SJG-1
SHG-2 |
SJA-1
SHA-2 |
350 |
8
6 |
230
460-575 |
6 |
KG-1
SHA-3 |
KA-1
SHA-3 |
400 |
8
6 |
230
460-575 |
6 |
KG-1
SHG-3 |
KA-1
SHA-1 |
450 |
8
7 |
230
460-575 |
6 |
KG-1
SJG-2 |
KA-1
JA-2 |
500 |
7 |
460-575 |
6 |
SJG-2 |
SJA-2 |
600 |
7 |
460-575 |
6 |
SJG-2 |
SJA-2 |
700 |
8 |
460-575 |
6 |
KG-1 |
KA-1 |
800 |
8 |
460-575 |
6 |
KG-1 |
KA-1 |
900 |
8 |
460-575 |
6 |
KA-1 |
KA-1 |
[Back to Top]