Square D POWERPACT Electronic Trip Circuit Breakers
with MICROLOGIC Trip Units
Features
-
800, 1200, 2500 A Frames (UL)
-
1250 and 3200 A frames (IEC)
-
Rated for AC voltage systems through 600 V
-
Interrupting Ratings up to 125/100/50 kA at 240/480/600 Vac (UL)
-
North American Standards: UL489, CSA C22.2 and NMX J-266
-
International Standard: IEC: 947-2
-
Full complement of field installable devices common to all standards
-
Four interchangeable trip unit models from which to choose
-
Available POWERLOGIC based power metering and monitoring capabilities
-
Available protective relay functions as
defined by ANSI C37.2 and C37.90
Top
Square D MAG-GARD Motor Circuit Protectors
MAG-GARD motor circuit protectors provide protection for short circuit
conditions only. The trip unit has a single adjustment for
instantaneous pickup that, if exceeded, will trip the circuit breaker
with no intentional delay. Square D MAG-GARD circuit breakers are UL
recognized components and comply with NEC requirements for providing
motor short-circuit protection when installed as part of a UL Listed
combination controller having motor overload protection. Interrupt
ratings are established for these UL Listed combination.
Square D MAG-GARD circuit breakers are available in "J" construction only and
will accept the same lugs and accessories as equivalent POWERPACT
electronic trip circuit breakers. MAG-GARD circuit breakers will
not accept any communications or other trip unit accessories.
Top
Interrupting Ratings
Square D thermal-magnetic molded case circuit breaker can be standard
interrupting, high interrupting, extra high interrupting, and time
current limiting in construction and are UL Listed for the interrupting
ratings shown below.
UL recognizes component combinations (circuit breaker / circuit breaker
and fuse / circuit breaker) for series connected interrupting ratings.
All series rated combinations are marked on the end use equipment along
with the statement, "Caution - Series Rated System."
UL Listed
Interrupting Ratings in kA (RMS Symmetrical Amperes)
|
|
UL Listed Interrupting
Ratings (in kA) |
Amp Capacity |
Catalog Prefix |
Maximum Voltage |
240Vac |
480Vac |
600Vac |
125Vdc |
250Vdc |
500Vdc |
Standard Interrupting |
15-100A |
FA |
600Vac
480Vac
240Vac |
25
25
10 |
18
18
-- |
14
--
-- |
5
10
5 |
5
10
5 |
--
--
-- |
70-250A |
KA |
600Vac |
42 |
25 |
22 |
10 |
10 |
-- |
125-600A |
LA |
600Vac |
42 |
30 |
22 |
10 |
10 |
-- |
300-1000A |
MA |
600Vac |
42 |
30 |
22 |
10 |
10 |
-- |
600-1200A |
NA |
600Vac |
100 |
50 |
25 |
-- |
-- |
-- |
600-2000A |
PA |
600Vac |
65 |
50 |
42 |
-- |
-- |
-- |
High Interrupting |
15-100A |
FH |
600Vac |
65 |
25 |
18 |
10 |
-- |
20 |
70-250A |
KH |
600Vac |
65 |
35 |
25 |
10 |
-- |
20 |
125-400A |
LH |
600Vac |
65 |
35 |
25 |
14 |
14 |
20 |
300-1000A |
MH |
600Vac |
65 |
65 |
25 |
-- |
-- |
20 |
600-2000A |
PH |
600Vac |
125 |
100 |
65 |
-- |
-- |
-- |
|
15-100A |
FH-DC |
500Vac |
-- |
-- |
-- |
-- |
-- |
20 |
70-250A |
KH-DC |
500Vac |
-- |
-- |
-- |
-- |
-- |
20 |
125-400A |
LH-DC |
500Vac |
-- |
-- |
-- |
-- |
-- |
20 |
300-1000A |
MH-DC |
500Vac |
-- |
-- |
-- |
-- |
-- |
20 |
600-2500A |
PA-DC |
500Vac |
-- |
-- |
-- |
-- |
-- |
20 |
Extra High Interrupting |
15-100A |
FC |
480Vac |
100 |
65 |
-- |
-- |
-- |
-- |
110-250A |
KC |
480Vac |
100 |
65 |
-- |
-- |
-- |
-- |
300-600A |
LC |
600Vac |
100 |
65 |
35 |
-- |
-- |
-- |
600-1200A |
NC |
600Vac |
125 |
100 |
65 |
-- |
-- |
-- |
1600-2500A |
PC |
600Vac |
125 |
100 |
65 |
-- |
-- |
-- |
Current Limiting |
20-100A |
FI |
600Vac |
200 |
200 |
100 |
-- |
-- |
-- |
110-250A |
KI |
600Vac |
200 |
200 |
100 |
-- |
-- |
-- |
300-600A |
LI |
600Vac |
200 |
200 |
100 |
-- |
-- |
-- |
Top