Continuous Ampere Ratings (UL Listed)
1 Pole, 120 Volts AC, 125 Volts DC
15-100 Amperes
2, 3 Pole, 240 Volts AC, 250 Volts DC
15-150 Amperes
Continuous Ampere Rating
Catalog Number 120 VAC
125 VDC240 VAC, 250 VDC 1 Pole 2 Pole 3 Pole 15
20
25
30
NE114015
NE114020
NE114025
NE114030
NE224015
NE224020
NE224025
NE224030
NE234015
NE234020
NE234025
NE234030
35
40
50
60
NE114035
NE114040
NE114050
NE114060
NE224035
NE224040
NE224050
NE224060
NE234035
NE234040
NE234050
NE234060
70
80
90
100
NE114070
NE114080
NE114090
NE114100
NE224070
NE224080
NE224090
NE224100
NE234070
NE234080
NE234090
NE234100
60 MCS
100 MCS
----
----
NE224060NA
NE224100NA
NE234060NA
NE234100NA
125
150
----
----
NE224125
NE224150
NE234125
NE234150
150 MCS
----
NE224150NA
NE234150NA
125
150
----
----
NEF425125
NEF425150
NEF435125
NEF435150
150 MCS
----
NEF425150NA
NEF435150NA
Specifications: Federal Pacific Circuit Breakers meet the following requirements and standards
UL Standards UL 489, UL 486B, and UL 1087
CSA Standard C22.2 No. 5
National Electrical Code
Federal Specification W-C-375B:
1 Pole, Class 11a, 12a
2, 3 Pole, Class 10b, 11b, 12b
Interrupting Ratings, Amperes
(UL Listed)120 Volts AC: 14,000 AIC
240 Volts AC: 14,000 AIC
125 Volts DC: 5,000 AIC
250 Volts DC: 10,000 AIC
Continuous Ampere Ratings (UL Listed)
1 Pole, 277 Volts AC, 125 Volts DC
15-100 Amperes
2 and 3 Pole, 480 Volts AC, 250 Volts DC
15-150 Amperes
Continuous Ampere Rating
Catalog Number 277 VAC
125 VDC480 VAC, 250 VDC 1 Pole 2 Pole 3 Pole 15
20
25
30
NEF214015
NEF214020
NEF214025
NEF214030
----
----
NEF425025
NEF425030
NEF435015
NEF435020
NEF435025
NEF435030
35
40
50
60
NEF214035
NEF214040
NEF214050
NEF214060
NEF425035
NEF425040
NEF425050
NEF425060
NEF435035
NEF435040
NEF435050
NEF435060
70
80
90
100
NEF214070
NEF214080
NEF214090
NEF214100
NEF425070
NEF425080
NEF425090
NEF425100
NEF435070
NEF435080
NEF435090
NEF435100
60 MCS
100 MCS
----
----
NEF425060NA
NEF425100NA
NEF435060NA
NEF435100NA
125
150
----
----
NEF425125
NEF425150
NEF435125
NEF435150
150 MCS
----
NEF425150NA
NEF435150NA
Interrupting Ratings, Amperes
(UL Listed)
120 Volts AC: 25,000 AIC
240 Volts AC: 18,000 AIC
277 Volts AC: 14,000 AIC
480 Volts DC: 14,000 AIC
125 Volts DC: 5,000 AIC
250 Volts DC: 10,000 AIC
Specifications
Federal Pacific Circuit Breakers meet the following requirements and standards
UL Standards UL 489, UL 486B, and UL 1087
CSA Standard C22.2 No. 5
National Electrical Code
Federal Specification W-C-375B:
1 Pole, Class 12c, 13a
2, 3 Pole, Class 13b, 18a