Southland
Electrical carries a
large selection of new surplus and used Bus Plugs.
Bus Plugs or bus duct switches are
used in Manufacturing and Industrial plants to distribute power in a
convenient way. Bus Duct with Bus Plugs allow the easy addition or
relocation of equipment. The electrical feeder to a machine can be
easily relocated to another location on the bus duct. Southland Electrical offers these Fusible and Circuit Breaker Bus Plugs with a One Year warranty
and the Southland Advantage: Low Cost, Fast Service and over Twenty
years of experience. Visit our ecommerce site to order online 24/7!
Pow-R-Way III Bus Plug*
*link will take you to out online store
Fusible Plug-in Units
Ampere Rating |
Enclosure 600 volt |
Enclosure 240 volt |
100% Neutral Stab |
50% Internal Ground Stab |
50% Isolated Ground Stab |
200% Neutral Stab |
Catalog Number |
Catalog Number |
Catalog Number |
Catalog Number |
Catalog Number |
Catalog Number |
30 |
P3F361R |
P3F321R |
P3FN100 |
P3FG100 |
P3FI100 |
P3F2N100 |
60 |
P3F362R |
P3F322R |
P3FN100 |
P3FG100 |
P3FI100 |
P3F2N100 |
100 |
P3F363R |
P3F323R |
P3FN100 |
P3FG100 |
P3FI100 |
P3F2N100 |
200 |
P3F364R |
P3F324R |
P3FN200 |
P3FG200 |
P3FI200 |
P3F2N200 |
400 |
P3F365R |
P3F325R |
P3FN400 |
P3FG400 |
P3FI400 |
|
600 |
P3F366R |
P3F326R |
P3FN600 |
P3FG800 |
P3FI800 |
|
800 |
P3F367T |
P3F327T |
P3FN800 |
P3FG800 |
P3FI800 |
|
Fusible Plug-in Units
Ampere Rating |
Enclosure 600 volt |
Enclosure 240 volt |
100% Neutral Stab |
50% Internal Ground Stab |
Class
R Fuse Clips( If Required) |
600 volts |
240 volts |
Catalog Number |
Catalog Number |
Catalog Number |
Catalog Number |
Catalog Number |
Catalog Number |
30 |
ITAP361 |
ITAP321 |
PWN110 |
PIGS104 |
RFK161 |
RFK121 |
60 |
ITAP362 |
ITAP322 |
PWN110 |
PIGS104 |
RFK262 |
RFK222 |
100 |
ITAP363 |
ITAP323 |
PWN110 |
PIGS104 |
RFK464 |
RFK464 |
200 |
ITAP364 |
ITAP324 |
PWN250 |
PIGS208 |
RFK464 |
RFK464 |
400 |
ITAP365 |
ITAP325 |
PWN400 |
PIGS208 |
RFK666 |
RFK666 |
600 |
ITAP366 |
ITAP326 |
PWN600 |
PIGS208 |
RFK666 |
RFK666 |
800 |
ITAP367 |
ITAP327 |
PWN800 |
PIGS208 |
|
|
Fusible Switch Horsepower Rating
Amperes Rating |
240 volts |
480 volts |
600 volts |
Nec Std. |
Max. |
Nec Std. |
Max. |
Nec Std. |
Max. |
30 |
3 |
7.5 |
5 |
15 |
7.5 |
20 |
60 |
7.5 |
15 |
15 |
30 |
15 |
50 |
100 |
15 |
30 |
25 |
60 |
30 |
75 |
200 |
25 |
60 |
50 |
125 |
60 |
150 |
400 |
50 |
125 |
100 |
250 |
125 |
350 |
600 |
75 |
200 |
150 |
400 |
200 |
500 |
800 |
100 |
250 |
200 |
500 |
250 |
500 |
Pow-R-Way - Fusible Units
Ampere Rating |
600 Volts |
240 Volts |
Neutral |
Ground |
Class R Fuse Clips |
600 Volts |
240 Volts |
30
60
100
200
400
600
800
1000
1200 |
ITAP361
ITAP362
ITAP363
ITAP364
ITAP365
ITAP366
ITAP367 |
ITAP321
ITAP322
ITAP323
ITAP324
ITAP325
ITAP326
ITAP367 |
PWN110
PWN110
PWN110
PWN250
PWN400
PWN600
PWN800 |
PIGS104
PIGS104
PIGS104
PIGS108
PIGS208
PIGS208
PIGS208 |
RFK161
RFK262
RFK464
RFK464
RFK666
RFK666 |
RFK121
RFK222
RFK464
RFK464
RFK666
RFK666 |
FUSES
Pow-R-Way - Circuit Breaker Units
Breaker Frame |
Enclosure |
Neutral |
Ground
|
EHD, FDB, FD, HFD, FDC
15-150 Amps |
IBPFD |
PWN110
PWN150 |
PIGS104 |
JDB, JD, HJD, JDC
70-250 Amps |
IBPJD |
PWN250 |
PIGS104 |
KDB, KD, HKD, KDC
250-400 Amps |
IBPKD |
PWN400 |
PIGS104 |
LDB, LD, HLD, LDC
300-600 Amps |
IBPLD |
PWN600 |
PIGS208 |
MC, HMC
500-800 Amps |
IBPMC |
PWN800 |
PIGS608 |
NC, HNC
900-1200 Amps |
|
|
|
FB TRI-PAC
15-100 Amps |
IBPFBP |
PWN110 |
PIGS104 |
LA TRI-PAC
125-400 Amps |
IBPLAP |
PWN400 |
PIGS104 |
NB TRI-PACE
500-800 Amps |
IBPN8P |
PWN800 |
PIGS208 |
FCL Current Limit-R
15-100 Amps |
IBPFCL |
PWN110 |
PIGS104 |
LCL Current Limit-R
125-400 Amps |
IBPLCL |
PWN400 |
|
[Back to Top]
Pow-R-Way - Bolt-On Units
Bolt on Units |
Breaker Frame |
Ampere Rating |
Enclosure |
Circuit Breaker Type |
EHD, FDB, FD, HFD, FDC |
15-150 |
IBFDBO |
JDB, JD, HJD |
70-250 |
IBPJDBO |
KDB, KD, HKD, KDC |
250-400 |
IBPKDBO |
LDB, LD, HLD, LDC |
300-600 |
IBPLDBO |
MC, HMC |
500-800 |
IBPMCBO |
NC, HNC |
900-1200 |
IBPNCBO |
FB (TRI-PAC) |
15-100 |
IBPFBPBO |
LA (TRI-PAC) |
125-400 |
IBPLAPBO |
NB (TRI-PAC) |
500-800 |
IBPNBPBO |
FCL Current Limit-R |
15-100 |
IBPFCLBO |
FCL Current Limit-R |
125-400 |
IBPCLBO |
Fusible Type |
240 Volts |
30
60
100
200
400
600
800
1200 |
ITAP321BO
ITAP322BO
ITAP323BO
ITAP324BO
ITAP325BO
ITAP326BO
ITAP327BO
ITAP329BO |
600 Volts |
30
60
100
200
400
600
800
1200 |
ITAP361BO
ITAP362BO
ITAP363BO
ITAP364BO
ITAP365BO
ITAP366BO
ITAP367BO
ITAP369BO |
[Back to Top]
Pow-R-Way Plug in Cable Tap Boxes Units
Ampere Rating |
3-Wire |
Neutral |
Ground |
225 |
IPTB225 |
PWN225 |
PIGS208 |
400 |
IPTB400 |
PWN400 |
PIGS208 |
600 |
IPTB600 |
PWN600 |
PIGS208 |
1000 |
IPTB1000 |
PWN1000 |
PIGS208 |
[Back to Top]
Cutler Hammer
QRT-PLUS
-
CP2HD
-
CP2FS
-
CP2CC
-
CP2KB
-
CP2KS
-
CP2LS
-
CP2MS
-
CP2FH3
-
CP2HKB3
-
CP2KH3
-
CP2LH3
-
CP2MH
|
Westinghouse
Pow-R-Way Breaker Type
Pow-R-Way II Breaker Type
Eaton/Cutler-Hammer Pow-R-Way III Bus Plug
-
IBPFD
-
IBPFBP
(TRI-PAC)
-
IBPJD
-
IBPKD
-
IBCLAP
(TRI-PAC)
-
IBPNBP
(TRI-PAC)
-
IBPFCL
-
IBPLCL
-
IBPMC
Fusible
Plug In
-
ITAP36
-
ITAP361
-
ITAP362
-
ITAP363
-
ITAP364
-
ITAP365
-
ITAP32
Tap
Boxes
-
IPTB400
-
IPTB600
-
ITPB1000
-
TAP
TOP |
|
Fusible
Panel board Switches &
Disconnects
Eaton/Cutler-Hammer Pow-R-Way III Bus Plug |